FANUC G60 single-direction positioning: why a move to X100 may first reach X95
An intermediate stop in 0i-F single-direction positioning explains how G60 preserves the final approach direction. One-axis calculations show additional travel, why an endpoint bounding box misses overrun, and the difference between one-shot and modal configuration.
Read article →